[av_heading heading=’Standardization of the organization’s server room -Part four’ tag=’h2′ style=” subheading_active=” show_icon=” icon=’ue800′ font=’entypo-fontello’ size=” av-medium-font-size-title=” av-small-font-size-title=” av-mini-font-size-title=” subheading_size=” av-medium-font-size=” av-small-font-size=” av-mini-font-size=” icon_size=” av-medium-font-size-1=” av-small-font-size-1=” av-mini-font-size-1=” color=” custom_font=” subheading_color=” seperator_color=” icon_color=” margin=” margin_sync=’true’ padding=’10’ icon_padding=’10’ headline_padding=” headline_padding_sync=’true’ link=” link_target=” id=” custom_class=” template_class=” av_uid=’av-lbiyytz8′ sc_version=’1.0′ admin_preview_bg=”][/av_heading] [av_textblock size=” av-medium-font-size=” av-small-font-size=” av-mini-font-size=” font_color=” color=” id=” custom_class=” template_class=” av_uid=’av-lbizgw1v’ sc_version=’1.0′ admin_preview_bg=”] In this part, we want to explain what is the difference between the design of the network infrastructure in the sense of cabling and networking of the organization’s users, with the standardization of the organization’s server room?

Network design and deployment in new buildings or under construction-part three

The main issue here is the vertical and horizontal cables of the organization, providing the best workstations, choosing the type of switch for user access, etc.

When placed in a large server room, there are a large number of servers that each support an application, or the Data center is made up of multiple layers of production, access, or switching layers, or there are many connections to the outside.

Organizations are part of a WAN or networking, or a large number of fiber optic inputs or outputs to your organization, where the number of equipment in your server room takes up more space.

And they require more electricity consumption and then produce more heat. Managing active or passive equipment in the data center is not easy.

  • The ANSI/TIA/EIA-942 standard, which was approved by the TR42.2 working group of the TIA Telecommunication Industry Association of the Technical and Engineering Committee TR-42, or the American National Standards Institute ANSI.
    This standard is intended for designers who need a broad understanding of data center design such as facility design, cabling system, electricity, architecture, security, etc.
  • BICSI-002-2011 standard or higher versions developed by BISCI Institute.
  • Instructions and guides of the non-active defense organization of the country in connection with the design, construction and management of standard server rooms and data centers.

استاندارد سازی اتاق سرور سازمان- Server roomWhat should we do ?

You should know that in designing a standard data center or a compact data center, you are dealing with a lot more items, lists and more.
What are the standard server room designs of your organization?
In short, know that you are on the side of these issues.

  • Architectural Design.
  • Design and arrangement of shelves.
  • Electrical design and calculations of the data center.
  • Server room cooling design and calculations.
  • Cabling design and calculations between racks, input and output cables of the data center.
  • Design and calculations of security systems.
  • Design of false floor and ceiling, walls, doors.
  • Calculation and prediction of required servers.
  • Calculations and predictions of required switch equipment.
  • Anticipation of required firewalls.
  • Anticipation of required routers.
  • Predicting rack accessories.
  • Prediction and calculation of server room lighting.

What not to do?

Standardizing the server room is much more expensive than setting up the whole building’s network
It will cost several tens of millions per square meter
The most important issues of data center standardization include electricity and cooling.

Source: arpco.blog